Product Name Size Tested Standard/Specification Rating Air Infiltration Water Test Pressure Structural Wind Load DP Rating
Casement - Clad CC-3678-2 AAMA/WDMA/CSA 101/I.S.2/A440-05 & 08 C-C50 0.03 cfm/ft² 7.5psf +/-75psf +/-50
French Casement - Clad CFC-2872-2 AAMA/WDMA/CSA 101/I.S.2/A440-05 C-R35 0.10 cfm/ft² 6.0psf +/-52.5psf +/-35
Push-out Casement - Clad POCC-3672 AAMA/WDMA/CSA 101/I.S.2/A440-05 C-LC30 0.03 cfm/ft² 7.5psf +60/-45psf +40/-30
Push-out French Casement - Clad POCFC-3672 AAMA/WDMA/CSA 101/I.S.2/A440-05 C-R40 0.08 cfm/ft² 6.0psf +/-60psf +/-40
Casement Picture - Clad CCP-7278 AAMA/WDMA/CSA 101/I.S.2/A440-05 FW-C50 0.01 cfm/ft² 7.5psf +/-75psf +/-50
Awning - Clad AC4836-12 AAMA/WDMA/CSA 101/I.S.2/A440-05 AP-C50 0.02 cfm/ft² 7.5psf +/-75psf +/-50
Awning - Clad AC6040 AAMA/WDMA/CSA 101/I.S.2/A440-05 AP-C50 0.01 cfm/ft² 7.5psf +/-75psf +/-50
Awning - Clad AC5448 AAMA/WDMA/CSA 101/I.S.2/A440-05 AP-C50 0.02 cfm/ft² 7.5psf +/-75psf +/-50
Awning - Clad AC4060 AAMA/WDMA/CSA 101/I.S.2/A440-05 AP-C50 0.01 cfm/ft² 7.5psf +/-75psf +/-50
Double Hung - Clad DCS4036-2 AAMA/WDMA/CSA 101/I.S.2/A440-05 H-LC30 0.08 cfm/ft² 4.5psf +/-45psf +/-30
Double Hung Eyebrow - Clad DCS4036-2 AAMA/WDMA/CSA 101/I.S.2/A440-05 H-LC30 0.08 cfm/ft² 4.5psf +/-45psf +/-30
Double Hung Picture - Clad DCSP6672 ANSI/AAMA/NWWDA 101/I.S.2-97 F-C40 0.01 cfm/ft² 6.0psf +/-60psf +/-40
Replacement Double Hung - Clad RDH4036 AAMA/WDMA/CSA 101/I.S.2/A440-05 H-LC30 0.03 cfm/ft² 4.5psf +/-45psf +/-30
Replacement Double Hung Picture - Clad FW-C50 AAMA/WDMA/CSA 101/I.S.2/A440-05 FW-C50 0.01 cfm/ft² 7.5psf +/-75psf +/-50
Glider - Clad GC7260 ANSI/AAMA/NWWDA 101/I.S.2-97 HS-LC25 0.19 cfm/ft² 3.75psf +/-37.5psf +/-25
Direct Set - Clad 77x77 AAMA/WDMA/CSA 101/I.S.2/A440-05 FW-C60 0.01 cfm/ft² 9psf +/-90psf +/-60

Hinged Door Products

(Back to top)

Hinged Door Products
Product Name Size Tested Standard/Specification Rating Air Infiltration Water Test Pressure Structural Wind Load DP Rating
Veranda Door - Clad CVD9080 AAMA/NWWDA 101/I.S.2-97 HGD-LC30 0.09 cfm/ft² 4.5psf +/-45psf +/-30
Inswing French Door - Clad ¹ CFD3080 AAMA/WDMA/CSA 101/I.S.2/A440-05 LW SHD-LC35 0.08 cfm/ft² 3.75psf +/-82.5psf +/-55
Inswing French Door - Clad ² CFD3080 AAMA/WDMA/CSA 101/I.S.2/A440-05 SHD-R20 0.05 cfm/ft² 3.0psf +/-30psf +/-20
Inswing French Door - Clad ¹ CFD6080 AAMA/NWWDA 101/I.S.2-97 HGD-LC25 0.13 cfm/ft² 3.75psf +37.5/-45psf +25/-30
Outswing French Door - Clad ¹ CFOD3080 AAMA/WDMA/CSA 101/I.S.2/A440-05 LW SHD-LC55 0.02 cfm/ft² 6.0psf +82.5/-90psf +/-55
Outswing French Door - Clad ² CFOD3080 AAMA/WDMA/CSA 101/I.S.2/A440-05 SHD-R20 0.02 cfm/ft² 4.5psf +/-30psf +/-20
Outswing French Door - Clad ¹ CFOD60610 AAMA/NWWDA 101/I.S.2-97 HGD-LC25 0.08 cfm/ft² 4.5psf +37.5/-45psf +25/-30

Legend

1. Requires Multi Point Hardware

2. Single Point Hardware

Sliding Door Products

(Back to top)

Sliding Door Products
Product Name Size Tested Standard/Specification Rating Air Infiltration Water Test Pressure Structural Wind Load DP Rating
Sliding Patio Door - Clad CPD8080 ANSI/AAMA/NWWDA 101/I.S.2-97 SGD-LC25 0.24 cfm/ft² 3.75psf +/-37.5psf +/-25
Sliding French Patio Door CFSD8080 ANSI/AAMA/NWWDA 101/I.S.2-97 SGD-R20 0.11 cfm/ft² 3.0psf +/-30psf +/-20
Sliding French Patio Door CFSD16080-4 ANSI/AAMA/NWWDA 101/I.S.2-97 SGD-R15 0.06 cfm/ft² 3.75psf +22.5/-30psf +/-15

High Performance Products

(Back to top)

High Performance Products
Product Name Size Tested Standard/Specification Rating Air Infiltration Water Test Pressure Structural Wind Load DP Rating
Double Hung - Clad ³ DCS3236 AAMA/WDMA/CSA 101/I.S.2/A440-05 H-LC50 0.11 cfm/ft² 7.5psf +/-75psf +/-50
French Sliding Door - Clad ³ CFSD8080 AAMA/WDMA/CSA 101/I.S.2/A440-05 & 08 SGD-LC50 0.17 cfm/ft² 7.5psf +/-75psf +/-50

Legend

3. Requires DP50 order specifications.

Impact Products

(Back to top)

Impact Products
Product Name Size Tested Standard/Specification Details
Casement - Clad CC3678-2 ASTM E 1886/1996-02 +50-50 PSF, Missile Level "D", Wind Zone 3
Casement Picture - Clad CCP6078 ASTM E 1886-97 to 05/1996-99 to 06 +50-50 PSF, Missile Level "D", Wind Zone 3
Awning - Clad AC 4836-13 ASTM E 1886-97 to 05/1996-99 to 06 +50-50 PSF, Missile Level "D", Wind Zone 3
Direct Set - Clad CDS-1 7272 ASTM E 1886-97 to 05/1996-99 to 06 +50-50 PSF, Missile Level "D", Wind Zone 3
French Door - Clad CFOD30610 ASTM E 1886-97 to 05/1996-99 to 06 +50-50 PSF, Missile Level "D", Wind Zone 3